UL-FC-000001

Pump Cavitation Test Case

KKSTEST-PUMP-001
StatusConfirmed
Failure Modes: Cavitation
Symptoms: High Vibration

Operating Conditions

Flow
450
Flow Unit
m³/h
Suction Pressure
1.2
Discharge Pressure
10
Pressure Unit
bar
Temperature
65
Temperature Unit
°C
Speed
2980
Speed Unit
rpm
Motor Current
42
Current Unit
A
Fluid
water

Failure

Primary Symptom
High Vibration
Failure Description
Pump developed abnormal noise and increased vibration during operation at elevated flow.
Failure Mechanism
Local pressure at the impeller inlet decreased sufficiently to promote vapor bubble formation and subsequent collapse in higher-pressure regions.

Evidence

Visual Findings
No internal inspection was performed for this test record.
Vibration Findings
Increased broadband vibration was observed during the affected operating condition.
Process Findings
Symptoms became more pronounced as operating flow increased.

Diagnosis and Root Cause

Probable Causes
Restricted suction conditions, insufficient NPSH margin, elevated flow operation, or suction-side pressure loss.
Confirmed Root Cause
Insufficient NPSH margin — TEST CASE ONLY.
Root Cause Evidence
Test diagnosis created solely to validate the UptimeLibrary Failure Case workflow.
Diagnostic Steps
Verify suction pressure, flow, fluid temperature, suction restrictions and NPSH margin before confirming cavitation.
Confidence Level
85
Root Causes: Insufficient NPSH

Actions

Immediate Action
Verify pump operating point and suction conditions.
Corrective Action
Inspect the suction system and restore the pump to the approved operating envelope.
Preventive Action
Trend suction pressure, flow and vibration and maintain adequate NPSH margin.
Verification Method
Confirm stable suction conditions and reduction in abnormal vibration/noise.
Lessons Learned
Cavitation should not be diagnosed from noise or vibration alone; hydraulic operating data must also be evaluated.

Reliability

Downtime Hours
2
Repair Hours
1
Repeat Failure
No